SII IP-6600-01 Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Drucken & Scannen SII IP-6600-01 herunter. SII IP-6600-01 Programming instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - DoorCom IP In-Home

DCIP 650-01ManualDoorCom IP In-Home

Seite 2 - Contents

104 Components for DC IP 650-...Programming, video server, DoorComDCA 740-01DoorCom Analog DCA 740-01, in switch panel housing, can be con-nected to a

Seite 3 - System conditions:

11VNG 602-02Video line rectier in a 10-grid housing.Primary: 230 V AC, 50/60 HzSecondary: 30 V DC, 1.1 A stabi-lized.For supply to the SIVS 610-... a

Seite 4 - In-Home bus: Video

12BPS 650-0 from V2.50Bus programming software for pro-gramming In-Home bus systems. For this, the programming interface PRI 602-... is also required

Seite 5 - Video communication via IP

13fijgha bc de5 Installation wiring diagramsTerminals DCIP 650-01Terminals and LEDs IPVS 600-01 a 12VDC power input for connecting the power supply

Seite 6

14LED displays SIVS 610-0LED signalling IPVS 600-...The IP video server IPVS 600-... has 3 LEDs which can display operating statuses and can provide a

Seite 7

15LED signalling SII 650-...The system interface In-Home bus SII 650-... is fitted with 2 LEDs under the device lid which display operating statuses a

Seite 8 - Bus camera module

165 Terminal assignmentSIVS 610-0Block diagram SIVS 610-0G Reference for the inputs E1–E4E4 Input 4, not usedE4 Input 3, not usedE4 Input 2, not usedE

Seite 9 - Input modules

175 Terminal assignmentSII 650-0Block diagram SII 650-0TaM/TbM In-Home bus: Video Input and outputE1+/E1- Input for signalling function, 4-30 V DC or

Seite 10

185 InstallationDCIP 650-01230 V AC230 V AC230 V ACSiedle VarioBTLM 650-...BTM 650-...BCMC 650-...BVNG 650-...ZBVNG 650-...TR 603-... VNG 602-...SII 6

Seite 11 - Interfaces, power supply

19FunctionUp to 29 PC users (Software Clients) of a network can be called from the door station. Calling, speech and door release via the Software Cli

Seite 12 - 4 Software

2Contents1 System description 3 2 Safety remarks 3System conditions 3 3 Structure DCIP 650-01 4Autocommunication via the tele-phone system with DCA 74

Seite 13 - Terminals DCIP 650-01

205 InstallationDCIP 650-01230 V AC230 V AC230 V ACSiedle VarioBTLM 650-...BTM 650-...BCMC 650-...BVNG 650-...ZBVG 650-...TR 603-... VNG 602-...SII 65

Seite 14 - LED displays SIVS 610-0

21In-Home bus VideoSingle-line system with DCA 740-...FunctionUp to 29 PC users (Software Clients) of a network can be called from the door station. C

Seite 15

225 InstallationDCIP 650-01230 V AC230 V AC230 V AC230 V ACSiedle VarioBTLM 650-...BTM 650-...BCMC 650-...BVNG 650-...ZBVNG 650-...ZBVG 650-...BVNG 65

Seite 16 - SIVS 610-0

23In-Home bus VideoMultiple line systemFunctionUp to 29PCusers (Software Clients) in a network can be called per SII650-.... In a multiple-line sy

Seite 17 - SII 650-0

24A number of steps have to be executed for commissioning the DCIP 650-... . The specied sequence must be adhered to without fail.• Prior to program

Seite 18 - 5 Installation

25Step 3 (only with multiple line system) Manually add SII650‑...In the BPS650-... , select the relevant line and add the SII650-... The address of

Seite 19 - Single line system

267 Client-SoftwareDCIP SC 600-0Installation of the Software ClientsThe Software Client DCIP SC 600-... (Ver. 1.1. or higher) must be installed on ea

Seite 20

27Possible error sources • No speech connection from the PC to the door. The microphone amplifier may not be activated. • Installation must take place

Seite 21

287 DoorCom DCA 740-01 8 DoorCom IPFactory setting IPVS 600-...The DoorCom Analog DCA 740-... is used as an interface between DoorCom IP and an analo

Seite 22

299 Measured valuesMeasurement values for DoorCom IP, to be measured using a digital multimeterIdle status min. max.Voltage +/ at the SIVS 610-... 24

Seite 23 - Multiple line system

3DoorCom IP In-HomeSiedle DoorCom IP links the Siedle In-Home bus: Video with the IP world. Door calls are transformed via the DoorCom IP and transmit

Seite 24 - 6 Commissioning

3010 Glossary IndexThe current issue of the “DoorCom IP” system manual is available from the download area under www.siedle.de.Technical additions or

Seite 26 - DCIP SC 600-0

S. Siedle & SöhneTelefon- und Telegrafenwerke OHGPostfach 115578113 FurtwangenBregstraße 178120 FurtwangenTelefon +49 7723 63-0Telefax +49 7723 63

Seite 27

4terminals TaM/TbM at the SII 650-... on the monitor branch. Dual termi-nals TaM/TbM are provided for loop through. Connection can alterna-tively take

Seite 28 - IPVS 600

5place with bus programming soft-ware BPS 650-...No programming is required for the DCA 740-01. For programming and conguration of the TC system, see

Seite 29 - 9 Measured values

6ClientPC user connected to a network.Full duplexTwo speaking users e.g. door sta-tion and remote station have an unrestricted speech connection. Open

Seite 30 - 10 Glossary Index

7USBThe universal serial bus (USB) is a serial bus system for connection of a computer to external devices. Devices or storage media equipped with USB

Seite 31

84 Components for DC IP 650-...Bus door loudspeaker module, Bus call button module, Bus camera moduleBTLM 650-04Bus door loudspeaker module for In-Hom

Seite 32

94 Components for DC IP 650-...Input modulesCOM 611-02Code lock module as an input unit for the placement of codes for con-trol functions in conjuncti